Product Code : RESPIRONICS A40
Product Description

As per noted name, we are offering our clients a superior quality range of Home Care Ventilator in Maharashtra, India. This ventilator is widely demanded in homes for respiratory patients to control breathing. At our vendors end, the offered ventilator is manufactured by dexterous deft professionals with using of excellent quality components and advanced techniques. Moreover, this Home Care Ventilator is precisely designed and available at pocket friendly prices within the committed time span.

Features:

  • Fitted with LCD
  • Excellent functionality
  • Less maintenance
  • Energy efficient

Technical Details:

BiPAP A40 specifications
Ventilation modes CPAP, S, S/T, PC, T, AVAPS-AE
Hybrid ventilation AVAPS (Average Volume Assured Pressure Support) AVAPS-AE
IPAP 4 – 40 cm H2O
EPAP 4 – 25 cm H2O
Target tidal volume (when AVAPS enabled) 200 – 1500 ml
Breath rate 0 – 40 bpm (4 – 40 bpm in T mode)
Inspiratory time 0.5 – 3 sec.
Triggering and cycling Auto-Trak Sensitive Auto-Trak Flow triggering
Rise time 1 (100 ms) – 6 (600 ms)
Size 21.6 cm W x 19 cm L x 11.5 cm H
Weight 2.1 Kgs (with power supply)
Noise level < 30 dBA at 10 cm H2O
Humidification System One humidity control and ‘Dry Box’ technology
Alarms Patient disconnection Apnea Low minute ventilation Low tidal volume (with AVAPS/AVAPS-AE only) High respiratory rate
Monitoring Pressure, tidal volume, minute ventilation, respiratory rate, leak, I/E ratio
Battery back up Detachable battery module: 5 hours at IPAP 12 cm H2O / EPAP 7 cm H2O and 12 bpm
DC power source 12 VDC, 5.0 A (external battery), 24 VDC, 4.2 A (power supply)
Data management EncorePro 2 and DirectView software Compatible with oximetry module Advanced detection of residual respiratory events (Apnea/Hypopnea Index, Obstructed Airway Apnea, Clear Airway Apnea, Hypopnea, Periodic Breathing, RERA, Large Leak and Snore)
Remote control Compatible with PC Direct
Polygraph and polysomnograph connections Direct connection to Alice PDx and Alice6 PSGs AOM to connect to most PSG systems


Guidelines for ventilation setup
Initial settings IPAP = 8 to 10 cmH2O, EPAP = 4 cmH2O and RR = 10 to 12 BPM
IPAP Increase IPAP if the patient wants more air, targeting patient tidal volume at 8 ml/Kg of ideal weight
EPAP • without OSAS (Obstructive Sleep Apnea Syndrome): 4 – 5 cmH2O
• with OSAS: increase EPAP to remove obstructive apnea events
• with intrinsic PEP (stable chronic COPD): 5 – 6 cmH2O
BPM Set to 2 – 3 BPM under patient’s spontaneous frequency
Rise time Obstructive patients prefer short rise time: from 1 to 4 (100 ms to 400 ms) Restrictive patients prefer long rise time: from 3 to 6 (300 ms to 600 ms)
Ti Set Ti between 25% and 33% for obstructive patients
Set Ti between 33% and 50% for restrictive patients
(refer to Conversion table )


A V A P S
OHS COPD Other restrictive diseases (NMD, etc.)
Vt target 8 to 10 ml/Kg of ideal body weight (refer to table opposite)
IPAP window (IPAPmin and IPAPmax) Allow a wide range of pressure variation to ensure the right pressure at the right time.
• IPAPmin = EPAP
• IPAPmax = 25 – 30    cmH2O
Allow a more restrictive pressure window to combine comfort and efficacy.
• IPAPmin = comfortable IPAP
• IPAPmax = IPAPmin + 5    cmH2O
Allow a more restrictive pressure window to combine comfort and safety.
• IPAPmin = efficient IPAP
• IPAPmax = IPAPmin + 5    cmH2O
AVAPS rate AVAPS rate setting depends on patient needs and clinical condition:
0.5 - 3 cmH2O/min so target tidal volume is reached smoothly
3 - 5 cmH2O/min so target tidal volume is reached more rapidly


 

Check patient arterial blood gases (PaCO2 and PaO2) and oxygen saturation (SpO2)
Conversion table to set the inspiratory time for controlled breaths
Set back up breath rate (BPM) I/E 1/3 Ti/Ttot 25% I/E 1/2 Ti/Ttot 33% I/E 1/1 Ti/Ttot 50%
10 1.5 s 2.0 s 3.0 s
11 1.4 s 1.8 s 2.7 s
12 1.3 s 1.7 s 2.5 s
13 1.2 s 1.5 s 2.3 s
14 1.1 s 1.4 s 2.1 s
15 1.0 s 1.3 s 2.0 s
16 0.9 s 1.3 s 1.8 s
17 0.9 s 1.2 s 1.7 s
18 0.8 s 1.1 s 1.6 s
19 0.8 s 1.1 s 1.5 s
20 0.8 s 1.0 s 1.5 s
21 0.7 s 1.0 s 1.4 s
22 0.7 s 0.9 s 1.3 s
23 0.7 s 0.9 s 1.3 s
24 0.6 s 0.8 s 1.2 s
25 0.6 s 0.8 s 1.2

 

Set the inspiratory time in seconds: Ti (Second) = 60/Respiratory rate x % Ti
 Conversion table to set the target tidal volume in relation to the ideal weight
Height Calculated ideal weight (if BMI = 23) Target Vte if 8 ml/Kg Target Vte if 10 ml/Kg
1.50 m 52.0 Kg 410 ml 520 ml
1.55 m 55.0 Kg 440 ml 550 ml
1.60 m 59.0 Kg 470 ml 590 ml
1.65 m 62.5 Kg 500 ml 620 ml
1.70 m 66.5 Kg 530 ml 660 ml
1.55 m 55.0 Kg 560 ml 700 ml
1.75 m 70.5 Kg 600 ml 740 ml
1.85 m 78.5 Kg 630 ml 780 ml
1.90 m 83.0 Kg 660 ml 830 ml
Calculated with an ideal Body Mass Index of 23 Kg/m2 (BMI=weight/height2)